Honeywell g. Manual. More information available at energy and, if not installed and used in accordance with the instructions, may. free pdf instructions. Find the office and computer equipment manual you need at ManualsOnline. Honeywell g Scanner User Manual. Page 1. Page 2. View and Download Honeywell g user manual online. General Purpose Handheld Linear Imager. g Scanner pdf manual download. Also for: gpdf.

Author: Grojar Dotaxe
Country: Chad
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 21 October 2013
Pages: 98
PDF File Size: 5.81 Mb
ePub File Size: 18.92 Mb
ISBN: 659-9-60094-990-1
Downloads: 58697
Price: Free* [*Free Regsitration Required]
Uploader: Akijinn

The information in this publication does not represent a commitment on the part of Honeywell. Honeywell shall not be liable for technical or editorial errors or omissions con- tained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.

Data Format Editor Commands Any changes or modifications made to this equipment not expressly approved by Honeywell International Inc. To maintain compliance with FCC Rules and Regulations, cables connected to this device must be shielded cables.

Nijverheidsweg 9 BT Eindhoven Mwnual Netherlands Honeywell shall not be liable for use of our product with equipment i.

Waste Electrical and Electronic Equipment In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal.

Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Unpacking the Imager After you open the shipping carton containing the g, take the following steps: If this is your interface and you do not 3080g to modify the settings, skip to Chapter If you programmed the imager for a different terminal ,anual and you want to change to a USB Keyboard PC or USB Keyboard Macscan one of the fol- lowing codes to program the g.

Scanning this code changes the terminal ID to Adaptue following is an example of a keyboard wedge connection: You will not hear a power-up beep because the g is factory defaulted to a USB connection. You must scan the with CR suffix Connect the power supply and plug into an outlet. You must scan the below to enable RS ability.

After scanning one of these codes, you must power cycle the cash register. This ensures that the entire code is scanned. Product Default Settings bar code below. Terminal ID Save Note: After scanning one of these codes, you must power cycle your computer.

Please refer to Honeywell website www. If you need to pro- gram adaptu keyboard for a country other than one listed above, scan the Program Keyboard Country bar code below, then scan the numeric bar code s for the appropriate country from the inside back cover, then the Save bar code.

Hand Held Products HANDHELD 3800G User Manual

The imager sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Stop Bits sets the stop bits at 1 or 2. RS handshaking is a set of rules concerning the exchange of data between serially communicating devices. Once the time-out value is reached, if there have been no further trigger pulls the imager reverts to the original hands free mode.

  C# 3.0 THE COMPLETE REFERENCE HERBERT SCHILDT PDF

At least part of a bar code must be within the window to be decoded or out- put by the imager. When the output sequence is Offthe bar code data is output to the host as the imager decodes it. This selection is unavailable when the Multiple Symbols Selection is turned on. Output Sequence Example In this example, you are scanning Code 93, Codeand Code 39 barcodes, but you want the image scanner to output Code 39 1st, Code 2nd, and Code 93 3rd, as shown below. Code 93 must be enabled to use this example.

When an output sequence is Requiredall output data must conform to an edited sequence or the image scanner will not transmit the output data to the host device.

The hex code for the No Read symbol is 9C. If additional menuing is required, Video Reverse must be disabled to read the menu bar codes and then re-enabled after menuing is completed. Scan the 2 hex digits from the cover of this manual or scan 9, 9 for all symbologies. A for the symbology from which you want to clear the prefix or suffix. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity.

Each delay is composed of a 5 millisecond step. You can program up to 99 steps of 5 ms each for a range of ms. To remove this delay, scan the Delay Length bar code, and set the number of steps to 0.

Scan the SAVE bar code using the back cover of this manual. If you are pro- page Programming Chart pageCode I. Scan the inside the back cover of Symbology The cursor is not moved by the FB command.

Honeywell 3800g User Manual

The imager will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format. Secondary Interface By switching secondary interface cables, the g imager, for example, can communicate with a portable data terminal secondary interface in addition to the host terminal primary interface.

See the table below for the secondary interfaces for the g. If you change the time-out duration for the secondary interface, the duration of the primary interface will also be changed. Scan the Hands Free Time-Out bar code, then scan the time-out duration frommilliseconds from the inside back cover, and Save. The minimum 3800h maximum lengths and the defaults are included with the respective symbologies.

When Check Character is set to Validate and Transmitthe imager will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data. The imager transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Scan the bar codes below to change the adaptuss length.

  ISLAMIC GEOMETRIC PATTERNS ERIC BLOUGH PDF

Refer to Message Length on page for additional information.

Honeywell Scanner g User Guide |

The data characters should then appear properly. Length on manuao for additional information. Use the bar codes below to turn concatenation on or off. Function Codes On bar code, below. The numeric system digit of a U. When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. If you need to read codes that lead with the 1 number sys- tem, use the UPC E1 selection. MSI mnaual codes printed with the specified type check character, but will not transmit the check character with the scanned data.

If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code must be off. Manuap the barcodes below to change the message length. Refer to Length page for additional information. Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. The following chart indicates the equivalents of these five characters for different countries.

Standard Product Default Settings bar code below. If you download new software into a unit, the user-programmed parameters are retained. You can modify the image settings and save the image settings to an INI file, which can be loaded later to capture new images.

Imaging also lets you preview the images continuously captured by the imager. Installing Visual Xpress from the Web 1. Access the Honeywell web site at www.

Click in the Quick Search text box and enter Visual Xpress. Click on Search Now. Click on the entry for Visual Xpress. When prompted, select Save File, and save the files to the c: The serial programming commands can be aadaptus in place of the programming bar codes. Both the serial commands and the programming bar codes will pro- gram the g. For complete descriptions and examples of each serial pro- gramming command, refer to the corresponding programming bar code in this manual.

When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period, exclamation point, comma, or semicolon in the command. Code 39 Check Char. Please see Customer Support on page for further information. Maintenance The g provides reliable and efficient operation with a minimum of care.

Although specific maintenance is not required, the following periodic checks ensure dependable scanner operation: Replacing the Interface Cable The standard interface cable is attached to the scanner with an pin modular connector.

The interface cable is designed to be field replaceable. Does the scanner read the bar code incorrectly? If the scanner reads a bar code, but the data is not displayed correctly on the host screen: