FREESTYLE OPTIUM MANUAL PDF

Ə. O. FreeStyle. Precision Neo. Blood Glucose and Ketone Monitoring System. Owner’s Setup Guide. User’s Manual a Abbott. FreeStyle Optium – It’s reassuring to have a reliable* friend by your side. Faqs neo. Got a question? Find the answer here. For more details please read our frequently asked questions about the FreeStyle Optium Neo. find out more.

Author: Sanris Samuzuru
Country: Ghana
Language: English (Spanish)
Genre: Love
Published (Last): 19 August 2006
Pages: 468
PDF File Size: 20.19 Mb
ePub File Size: 12.34 Mb
ISBN: 544-4-11717-148-3
Downloads: 26720
Price: Free* [*Free Regsitration Required]
Uploader: Meztisida

Definition of Symbols These symbols are associated with your meter. The European Iptium Directive requires separate Batch code collection of spent batteries, aiming to facilitate recycling and to protect the environment. The batteries in this product should be removed and disposed in accordance with local regulations for Catalogue number separate collection of spent batteries. Table of Contents Intended Use Observe caution when using around children. Use only FreeStyle Optium blood glucose test strips hazard.

Other test strips may produce inaccurate results. Time Date Format The hour flashes. Press until the correct hour appears.

Press to save The date format flashes. Press to change the date format.

Press the hour and to move to set minutes. Testing Your Blood Glucose Do not use expired test strips; they may produce inaccurate results.

Alternative Sites Performing a Blood Glucose Test Obtaining a blood sample from alternative sites — forearm, upper arm, and base of Open the foil test strip manjal at the notch and tear down to remove the the thumb — is subject to limitation. Contact your healthcare professional before test strip.

Abbott FreeStyle Optium Manuals

Hold the blood drop to the white area until the meter beeps if sound is on and The Apply Sample symbols appear next, indicating the meter is ready for the status bar appears on the display.

This indicates the test strip has obtained you to apply a sample to the test strip. The unit of measurement is preset. You cannot change glucose the result is LO, contact your healthcare this setting. Wash your hands with warm soapy water to ensure This display always appears when the meter is turned on. Thoroughly dry your hands. To warm the site, apply a Do not use the meter if the display check screen does not exactly match the warm dry pad or rub vigorously for a few seconds.

  ANSAB AL ASHRAF BY BALADHURI PDF

The blood is The meter beeps if sound is on when the result and appears on the drawn into the test strip. You cannot change this 0. When you open a control solution bottle for the first time, count forward 90 days and write this date on the control Do not use control solution past the expiry date.

Open the foil test strip packet at the notch and tear down to remove the Note: Press to mark the test as a control solution test.

The result should fall within the range.

Abbott FreeStyle Optium Manuals

Causes of out-of-range results include: Managing Your Results Your most recent result, with time and date if set it was obtained, appears next. The following symbols indicate the type of result: Freestyoe Blood Glucose Averages While in memory, press.

Your 7-day average appears. For more The blood glucose level may 1. Review the testing instructions. Check that you are using the correct strip for this meter. See test strip instructions for use for Defective meter or test strip 1. Remove the used strip and discard it The test does not start after re-application instructions. Maintaining the Meter 2.

If the meter includes a plastic tab, pull on the tab to remove the battery. If the meter does not include a plastic tab, push the battery upward to Replacing the Rfeestyle remove it.

The meter comes with a CR lithium coin cell battery installed. It provides power for about 1, tests. Cleaning the Meter Storing the Meter Store the meter in the carrying case freesfyle. Avoid getting dirt, dust, blood, control solution, or liquid in the meter test strip port. Clean the outside of the meter using a damp cloth and mild soap. Acceptable cleaning solutions include When countdown starts and ends.

Test strips See test strip instructions for use. Stays on during countdown; turns off 30 seconds after results Control solution See control solution instructions for use. Stays on while transferring results to a computer. Assay Method Amperometric electrochemistry Data Port Metabolic and clinical significance of ketosis. Special Topics in Endocrinology and Metabolism ; 4: Treatment of diabetic ketoacidosis using normalization of blood 3-hydroxybutyrate concentration as the endpoint of emergency management.

  ABB ESB 20-20 PDF

Page of 26 Go. National Phytopharma Joint-Stock Company. Opposite Radio Pakistan Transmission. Abbott Laboratories Singapore Pte Ltd.

Table of Contents Add to my manuals Add. Abbott diabetes care owner’s manual blood glucose monitor 2 pages. Abbott freestyle navigator ii blood glucose monitoring system 21 pages. Abbott freestyle navigator blood glucose monitoring system pages. Intended Use Observe caution when using around children. Time Time Date Format The frefstyle flashes. Alternative Sites Alternative Sites Performing a Blood Glucose Test Obtaining a blood sample from alternative sites — forearm, upper arm, and base of Open the foil test ffeestyle packet at the notch and tear down to remove the the thumb — is subject to limitation.

Page 9 Hold the blood drop to the white area until the meter beeps if sound is on and The Apply Sample symbols appear next, indicating the meter is ready for the status bar appears on the display. Managing Your Results Managing Your Results Your most recent result, with time and date if set it was obtained, appears next. Maintaining The Meter Maintaining the Meter 2.

Page 25 Beeper On: This manual also for: Comments to this Manuals Your Name. Enter text from picture: How do I properly change the battery in FreeStyle Lite? I am using Freestyle Optium H. After replacing a new battery, the monitor shows error E – 6.

I did try all the options shown in the manual. The monitor still shows error E- 6. Pl mannual and do the needful. When I fix strip MEM displays please rectify this problem. By pressing ‘print’ button you will print only current page. To print the manual completely, please, download it.

Don’t show me this message again. Got it, continue to print. Don’t have an account?